Servo motors - Motor options

    Brake COMBIPERM

    Connection with power connector

    Technical data

    MotorBrakeMbr
    [Nm]
    JB
    [kgcm²]
    P20
    [W]
    t2
    [ms]
    t1=
    [ms]
    t11=
    [ms]
    WR0.1
    [J*10^6]
    WRmax
    [J*10^3]
    ~kg
    TA1, TA2BP0320.0681125620.415.30.2
    TA3BP054.50.181235720.5880.4
    TA4BP0690.541840720.89110.6
    TA5BP07181.6624501031.29141
    TA6BP08365.5626902232.9302
    MotorBrakeMbr
    [lb.in.]
    JB
    [lb in²]
    P20
    [W]
    t2
    [ms]
    t1=
    [ms]
    t11=
    [ms]
    WR0.1
    [J*10^6]
    WRmax
    [J*10^3]
    ~lb
    TA1, TA2BP03180.21125620.415.30.4
    TA3BP05400.531235720.5880.9
    TA4BP06801.581840720.89111.3
    TA5BP071594.8624501031.29142.2
    TA6BP0832016.2726902232.9304.4

    Brake COMBISTOP

    Connection with power connector

    Technical data

    MotorBrakeMbr
    [Nm]
    JB
    [kgcm²]
    P20
    [W]
    t2
    [ms]
    t11=
    [ms]
    WR0.1
    [J*10^6]
    WRmax
    [J*10^3]
    ~kg
    TA3BF0270.318≤90≤257.54.81.5
    TA4BF03160.720≤150≤6012.56.12.5
    TA5BF04361.425≤220≤12019.110.64.8
    TA6BF05703.530≤420≤6028.8328.3
    Mbr
    Static braking torque after completed run-in phase (20°C)
    JB
    Inertia
    P20
    Excitation rating at 20°C
    t2
    Release time, time from connecting the current to the beginning of torque decrease
    t1=
    Engaging time: Time from disconnecting of current until the rated torque is attained
    t11=
    Engaging delay time: Time from disconnecting of current until the torque rises
    WR0.1
    friction work until 0.1mm abrasion
    WRmax
    permissible friction work for emergency stop from 3000 1/min

    The specified switching times apply to nominal clearance and nominal torque. It relates to average values and depends on the type of rectification and coil temperature.

    Motor protection

    The following motor protection can be supplied:

    Additional inertia

    To improve the control characteristics of the servo system with high external masses, the servomotors TA can be equipped with an additional inertia.

    MotorJz
    [kgcm²]
    TA3S, TA3M2.6
    TA41, TA4211
    TA51, TA5228
    TA61, TA62130

    Electrical Connection

    Motor TA1..TA5

    Power connector Size 1, 8pole, Counterplug optional

    Pin 1PE 34A B C D
    SignalU WVBrake +Brake -TWTW

    Motor TA6

    Power connector Size 1.5, 8pole, Counterplug optional

    Pin UVWPE + - 1 2
    SignalUVW Brake +Brake -TWTW

    F – Forced ventilation

    Voltage/Frequency: 3~ 400V 50Hz

    Rated current of forced ventilation: 0.14A

    Power connector 4pole, Counterplug included

    Pin 123PE
    SignalUVW

    Position of motor connection for geared motors

    Example: Motor connection 90, Plug connector radial