Three phase motors - Motor options

    Motor protection

    The following motor protection can be supplied:

    Anti condensation heating

    condensation drain hole

    The condensation drain holes are located on the lower side of the motor, depending on the mounting position of the motor.

    The condensation drain holes are closed at the factory and must be opened to drain condensate.

    high inertia fan

    MotorJz
    [kgcm²]
    DM639.7
    DM7116
    DM8028
    DM9051
    DM100, DM90LB101
    DM112, DM100LA, DM100LE154

    Protection cowl

    The protection cowl prevents the penetration of foreign objects or liquids when the motor is mounted in vertical position.

    MotorL4AC1
    DM63..DM8026122
    DM90..DM10030176
    DM112..DM13230220
    DM16040310
    DA180..DA22543240/338 1)

    1) Dimension for forced ventilation

    Second shaft end WE and handwheel

    The second shaft end can be used for fixing a handwheel or for radial force free transmission of the motor torque.

    If radial forces apply to the second shaft end, please consult the manufacturer.

    D13D14D15E13E14E15E16E17F13G13
    DM63
    DM71
    11100M42328163.544412.5
    DM80
    DM90
    DM100
    DM112
    14160M5303522444516
    DM13219160M6404532454621.5
    DM16038250M12808570598.51041
    DA180
    DA200
    DA225
    38250M12809070598.51041

    Position of terminal box

    Example: 270C is for terminal box at 270, Cable lead in C

    The position of other motor options (manual brake release, connection of forced ventilation, connection of encoder) is specified with the same method, independently, if different from position of terminal box.

    Example: 90A, Manual brake release 270

    GZ00E005000

    Cable lead in

    normal TW B
    F
    B + TW
    B + F
    F + TW
    B + TW + F
    DM63..DM1121xM252xM252xM252xM25+1xM161xM25+3xM16
    DM1322xM322xM32+1xM162xM322xM32+2xM162xM32+2xM16
    DM1602xM322xM32+1xM162xM322xM32+2xM162xM32+2xM16
    DA1802xM402xM40+1xM162xM402xM40+1xM162xM40+1xM16
    DA200..DA2252xM502xM50+1xM162xM502xM50+1xM162xM50+1xM16
    B
    Brake
    TW
    Motor protection TW, TS, KTY or PT
    F
    Forced ventilation

    Plug connector HAN 10ES

    Plug connector M23

    Motors: DM63..DM112

    Power connector, Size 1, 8pole
    Counterplug optional

    Brake: Umax=250V

    Pin 1PE 34A B C D
    SignalU WVBrake +Brake -TWTW

    Plug connector M40

    Motors: DM132..DM160

    Power connector Size 1.5, 8pole
    Counterplug optional

    Brake: Umax=250V

    Pin UVWPE + - 1 2
    SignalUVW Brake +Brake -TWTW