Three phase motors DM/DA - Forced ventilation

    Electrical Connection

    connection via contacts in terminal box

    Wiring diagram: GZ00X000020

    50 HZ60 HZ
    CBUnImaxPmaxUnImaxPmax
    DM71..DM132
    Motor Q000F100Q00 3~230/400V
    3~ Y346-525V0.19A89W380-575V0.16A99W
    3~ ∆200-290V0.31A85W220-332V0.29A103W
    1~ ┴ ∆3µF230-277V0.28A71W230-277V0.34A94W
    Motor Q000F200Q00 3~133/230V
    3~ Y174-234V0.52A102W174-234V0.36A94W
    3~ ∆100-135V0.89A102W100-135V0.64A93W
    1~ ┴ ∆12µF100-135V0.88A87W100-135V0.73A92W
    DM160
    Motor QX00F100Q00 3~230/400V
    3~ Y346-525V0.37A160W380-575V0.32A180W
    3~ ∆200-303V0.64A160W220-332V0.55A180W
    1~ ┴ ∆6µF230-277V0.52A125W230-277V0.61A163W
    DA180..DA225
    Motor QY00F100Q00 3~230/400V
    3~ Y346-525V0.74A314W380-575V0.62A391W
    3~ ∆200-303V1.28A314W220-332V1.08A391W
    1~ ┴ ∆12µF230-277V1.05A246W230-277V1.52A390W
    Un
    Range of voltage
    Imax
    permissible current
    Pmax
    max. power input
    CB
    service capacitor

    Startup

    Inspection and maintenance